Carrier HVAC Problem

Filed under Uncategorized by on . Comment#

Comments on Carrier HVAC Problem Leave a Comment

March 13, 2008

karrennic @ 3:16 pm #

i take it you havent seen a heatexchange before. by the way while the panel is of the blower moter is not running normally. Amps will be high and air flow will be low…..

madcitysw @ 5:46 pm #

Yes, I seen a hx before, but we found the problem anyway. It turns out since the ceilings were high in the playground, the heat would not come down. So we had to turn on the ceiling fans on in order for everything to work like it did before.

March 24, 2008

7montecarlo5 @ 11:26 pm #

Tighten up that belt and replace them filters boy!

April 12, 2008

dead995 @ 7:49 am #

if its a 48*j unit check the belt they had a problem with the motor mounting plate it was flexing through the blower out of wack hsg is 3pcs very loud

April 28, 2008

shodanxx @ 12:53 pm #

why are the tubes all dented like that ?

July 2, 2008

stoek3591 @ 9:16 pm #

that problem is a crack in the heat exchanger…there was a roll out of the flame

July 19, 2008

aljohnallen @ 5:55 pm #

Needs a new foofoo valve

August 11, 2008

cheetawolf @ 4:07 pm #

wats that?

August 12, 2008

aljohnallen @ 12:35 pm #

lol its a joke,,same as if u running pipes and no where to put a bracket ,then you need a sky hook lol..Carrier great stuff ,strong rugged ,but the wiring is a mess.Trane better for wiring.Large chillers any way..worked in middle east ,mainly carrier ,great chillers..Freidrich and zamil too ,that stuff not so good.oh carrier flo tronics very good.we had 125 ton chillers,in 10 yrs never changed a compressor..just the wiring lol,its a mess…

August 20, 2008

dkpd1581 @ 6:50 pm #

The dents help to slow down the flue gasses and allow them more time to stay in contact with the metal exchanger. This increases heat transfer and thus efficiency. They also – to a lesser extent – increase the surface area of the exchanger tube and again increase efficiency.

September 10, 2008

hvacrdude1 @ 3:53 pm #

HvacrTalk . com welcomes Techs contractors and consumers to join free and discuss and trade infor and learn meet others in the trade. good links and resources…all you need is a valid email to activate your account.

February 13, 2009

KeithRitchie1 @ 10:03 pm #

is the tech a mute?

June 20, 2009

SNL0907 @ 7:34 pm #

If there are cracks or holes in the heat exchanger, replace it!
What were you considering? patching it?

June 27, 2009

TehMG @ 12:47 pm #

Wow, that unit looks in really poor shape, rust everywhere. Especially on the heat exchanger, not a good thing.

August 8, 2009

jmgeorge721 @ 11:08 am #

those are called baffels

August 22, 2009

joseborikua28 @ 8:15 am #

you need a brand new unit …. LOL .PROBLEM RESOLVE LOLOL

December 31, 2009

Rinconmaniac @ 1:21 pm #

I love coming across these units. Easy money!